Free download. Book file PDF easily for everyone and every device. You can download and read online Animal Waste and Hazardous Substances: Current Laws and Legislative Issues file PDF Book only if you are registered here. And also you can download or read online all Book PDF file that related with Animal Waste and Hazardous Substances: Current Laws and Legislative Issues book. Happy reading Animal Waste and Hazardous Substances: Current Laws and Legislative Issues Bookeveryone. Download file Free Book PDF Animal Waste and Hazardous Substances: Current Laws and Legislative Issues at Complete PDF Library. This Book have some digital formats such us :paperbook, ebook, kindle, epub, fb2 and another formats. Here is The CompletePDF Book Library. It's free to register here to get Book file PDF Animal Waste and Hazardous Substances: Current Laws and Legislative Issues Pocket Guide.

A PCBU who directs the transportation of a class 1 substance must not stop during transportation, except as a result of an accident, incident, or emergency, or urgent refuelling, or as required under the Land Transport Act or any regulations or rules made under that Act. This regulation does not limit or otherwise affect the provisions of the Land Transport Act , or any regulations or rules made under that Act, and those provisions prevail in the event of any inconsistency between them and this regulation.

NZS means the standard on Gas detection and odorization. RLEL O means revised lower explosive limit, being the concentration of flammable gas, vapour, or mist in an atmosphere containing a different proportion of oxygen than standard air, below which an explosive gas atmosphere will not be formed. RUEL O means revised upper explosive limit, being the concentration of flammable gas, vapour, or mist in an atmosphere containing a different proportion of oxygen than standard air, above which an explosive gas atmosphere will not be formed.

UEL means upper explosive limit, being the concentration of flammable gas, vapour, or mist in standard air, above which an explosive gas atmosphere will not be formed. This Part does not apply to anhydrous ammonia that is contained in plant in which anhydrous ammonia is used as a refrigerant. A PCBU with management or control of a class 2, 3, or 4 substance must ensure that the substance is held at a hazardous substance location or at a transit depot if the quantity exceeds that specified in table 4 in Schedule 9 for the substance for more than—.

A PCBU with management or control of a class 2, 3, or 4 substance in a quantity specified in table 2 in Schedule 9 must ensure that the substance, if left unattended, is—. Except where the ignition of the substance is intended, a PCBU with management or control of work using a class 2, 3, or 4 substance must ensure that—. For the purposes of this regulation, a class 2, 3, or 4 substance is incompatible with a class 1, 2, 3, 4, 5, 6, or 8 substance as set out in table 1 in Schedule 9.

A PCBU with management or control of work using a class 2. If any electrical installation or any electrical appliance within the scope of the Electricity Safety Regulations is located within a hazardous area referred to in regulation If electrical equipment is installed on a ship, vessel, or boat other than a pleasure vessel containing connectible installations , the controls imposed on that electrical equipment under the Act are the same controls as are included in those parts of the Maritime Rules made under the Maritime Transport Act that relate to hazardous areas.

If electrical equipment is installed on any train, locomotive, tram, or trolley bus, the controls imposed on that electrical equipment under the Act are the same controls as are included in those parts of the Land Transport Act , and regulations or rules made under that Act, that relate to hazardous areas.

If any electrical equipment is installed on an aircraft that is under the jurisdiction of the Civil Aviation Rules, the controls imposed on that electrical equipment under the Act are the same controls as are included in those parts of the Civil Aviation Rules that relate to hazardous areas. If any electrical equipment is used within a hazardous area referred to in regulation For the purposes of subclause 1 , electrical appliance and electrical installation have the same meanings as in section 2 1 of the Electricity Act Unless a class 2.

Despite regulation An FVD system must have at least 4 permanently mounted continuously operating detection heads, in locations that will enable the detection heads to detect the presence of escaped gas.


  • Waste management;
  • Words of Love.
  • Démences (Terreur) (French Edition);

Subclauses 1 to 5 do not apply to a PCBU involved in the manufacture of LPG, propane, butane, or isobutane in relation to the manufacturing process. A PCBU with management or control of a refrigeration system that contains LPG, propane, butane, isobutane, or other flammable gas refrigerant as an integral part of that refrigeration system must ensure that the quantity and the means of containing the LPG, propane, butane, isobutane, or other flammable gas refrigerant comply with—. A PCBU who elects under regulation In this set of conditions, in any situation except situations covered by regulation At any place where the quantity of class 2.

Subclauses 3 , 4 , and 5 do not apply to a vehicle, a ship, or an aircraft at the dispensing unit of a refuelling outlet if, when petrol, aviation gasoline, racing gasoline, or LPG is being delivered to the fuel tank of the vehicle, ship, or aircraft,—.

Despite subclause 7 , a ship or an aircraft that is being refuelled with class 3.

Hazardous Substances and New Organisms Act 1996

A PCBU with management or control of any aircraft that is being refuelled must, in addition to complying with subclause 7 or 8 , also comply with the requirements of the Civil Aviation Rules relating to refuelling of aircraft. The requirements of regulation A class 2. At any place where a class 2. Compliance with sections 5—2 and 5—4 of NFPA 86 relating to the matters described in regulation A revised auto-ignition temperature must be established for the maximum proportion of oxygen to air expected to be experienced within the system, and—.

A PCBU with management or control of a class 3. A PCBU with management or control of any place within a workplace where a class 3. The PCBU with management or control of any place within a workplace where a class 4. A PCBU with management or control of class 4.

Animal waste and hazardous substances : current laws and legislative issues

A PCBU with management or control of a class 4. Where a class 4. A PCBU with management or control of work using a class 3. A PCBU with management or control of a place within a workplace where any class 2, 3, or 4 substance is located must establish in that place 1 or more hazardous substance locations where the substance is to be situated if the substance is present—. The PCBU with management or control of the hazardous substance location must notify WorkSafe at least 30 working days or, in the case of LPG, at least 5 working days before the commissioning of the hazardous substance location as a place for accommodating class 2, 3, or 4 substances of—.

Animal Waste Regulation Fact Sheet Now Available | National Hog Farmer

The PCBU with management or control of the hazardous substance location must ensure that the requirements of regulation The PCBU with management or control of the hazardous substance location must ensure that,—. This regulation does not apply to a PCBU with management or control of a tank wagon that is used to refuel aircraft carrying out the aerial application of a substance while—. A PCBU with management or control of a hazardous substance location at which a class 3. If class 3. In addition to subclause 2 , the PCBU must ensure that where class 4.

For the purposes of regulation The PCBU with management or control of the place must ensure that there is a system in place that, depending on the capacities of the container or containers in which the substances are held, complies with,—. If 2 or more containers of different capacities as described in regulations The PCBU must ensure, in relation to a stationary containment system at that place, that the following controls can be instituted in or in respect of the system:.

For the purposes of this regulation and regulations E10, E85, petrol, aviation gasoline, or racing gasoline in total quantities of less than 1 L; or. E10, E85, petrol, aviation gasoline, racing gasoline, kerosene, or diesel fuel in total quantities of less than 2 L contained in a tank wagon or in secure containers, each individual container having a capacity of less than L, located so that any spillage will not endanger any building or flow into any stream, lake, or natural water, and where the proposed or actual duration of the storage is for a continuous period of less than 14 days.

If pooling substances that are class 3 or 4 substances are held above ground in a place within a workplace in containers each of which has a capacity of 60 L or less,—. If pooling substances that are class 3 or 4 substances are held above ground in a place within a workplace in containers 1 or more of which have a capacity of more than 60 L but none of which has a capacity of more than L,—. This regulation does not apply to a stationary container to which regulation If pooling substances that are class 3 or 4 substances are held above ground in a place within a workplace in containers 1 or more of which have a capacity of more than L,—.

A PCBU with management or control of a hazardous substance location where class 2. This regulation does not apply to a PCBU with management or control of a hazardous substance location on a farm of not less than 4 ha, where the combined quantity of each class 3. A PCBU with management or control of a hazardous substance location where class 3. A PCBU with management or control of a transit depot where there is present a quantity of any class 2, 3, or 4 substance greater than the quantity specified in table 4 in Schedule 9 for that substance must,—.

What Does Environmental Law Cover?

AS — means the standard on The storage and handling of flammable and combustible liquids. NZS NZS means the standard on Automatic fire sprinkler systems. A PCBU with management or control of work using a hazardous substance to which this Part applies must ensure that the adverse effects of an unintended ignition of the substance are controlled in accordance with this Part.

This subpart applies to a class 2. This subpart does not apply to a location when the aggregate quantity of hazardous substances present is less than or equal to—. A PCBU with management or control of a vehicle filling point for a class 2. A PCBU with management or control of a cylinder must ensure that it is separated from—. Subclause 3 does not apply to the storage of a class 2. A PCBU with management or control of an above ground stationary tank, transportable container, or tank wagon must ensure that it is separated from—. A PCBU with management or control of a tank fill transfer point that is connected to an above ground stationary tank must ensure that it is separated from—.

A PCBU with management or control of 1 or more cylinders containing a class 2.

chapter and author info

A PCBU with management or control of cylinders that are located within 1 m of a building and that, individually or in aggregate, as the case may be, contain up to kg of a class 2. A PCBU with management or control of an above ground stationary tank, transportable container, or tank wagon that contains a class 2.


  1. Armed for Personal Defense;
  2. Fiddlers Song.
  3. Monday musings on laptops and midriffs.
  4. Animal Waste and Hazardous Substances: Current Laws and Legislative Issues - Digital Library!
  5. Kurt Tucholskys Journalismuskritik: Kritik als Berufsstörung (German Edition).
  6. Bath Time Bubbles.
  7. The $52.00 Pizza.
  8. Despite subclause 1 , a tank fill zone need not be separated from a protected place by any more than 15 m. Despite subclause 1 , a PCBU with management or control of an above ground stationary tank, transportable container, or tank wagon that contains LPG, propane, butane, or isobutane, and each tank fill transfer point connected to them, must ensure that it is separated from—. Despite subclause 3 , a tank fill transfer point is not required to be separated from a protected place by more than 15 m.

    New Zealand Legislation. Home Advanced search Browse About this site. Quick search HelpQuickSearch? My recent searches. Search within this Legislative Instrument. By clauses View whole 3. Add to web feed Order a commercial print.

    Reprint as at 1 July Note Changes authorised by subpart 2 of Part 2 of the Legislation Act have been made in this official reprint.